Abstract
Elevated temperature components must be designed against both pressure and thermal loads. In the case of sodium circuits of fast breeder reactors, a restriction from the pressure load becomes small because of the high boiling point of sodium. Design approaches for thermal loads (displacement-controlled) are compared with those against pressure loads (load-controlled). Considering differences between those two approaches, a concept of the elevated temperature design standard that takes the nature of thermal loads fully into account is propcsed. This concept is a basis of load evaluation techniques and an inelastic analysis guide, that are being developed. Finally, problems and plans to realize the above concept are discussed.
| Translated title of the contribution | 耐熱設計思想に基づく高温構造設計基準の検討 |
|---|---|
| Original language | Japanese |
| Pages (from-to) | 26 - 38 |
| Journal | 圧力技術 |
| Volume | 39 |
| Issue number | 5 |
| DOIs | |
| State | Published - 25 Sep 2001 |