2804 高速炉の直管型2重管蒸気発生器管板の熱応力評価 : (1)熱応力発生機構(S10-2 熱応力(2),S10 熱応力,応力特異性と強度評価)

Translated title of the contribution: 2804 Thermal Stress Evaluation of Tubesheet Structures for Double-Wall-Tube Steam Generators of FBRs : (1) Study of Stress Inducement Mechanism

笠原 直人, 高正 英樹, 安藤 勝訓, Naoto KASAHARA

Research output: Contribution to journalArticle

Abstract

Tubesheet structures utilized in heat exchangers have complex perforated portions. For design analysis of these structures, axi-symmetric models with equivalent materials of perforated plate are conventionally adopted to simplify perforated portions. Double-wall-tube steam generators expected for commercial FBRs require new type of tubesheets, where conventional design methods are not applicable. Therefore, JAEA started R & Ds to develop a design by analysis method for these structures. This paper reports on the mechanism of thermal stress developments in new tubesheets with an associated paper.
Translated title of the contribution2804 Thermal Stress Evaluation of Tubesheet Structures for Double-Wall-Tube Steam Generators of FBRs : (1) Study of Stress Inducement Mechanism
Original languageJapanese
Pages (from-to)683 - 684
JournalThe proceedings of the JSME annual meeting
Volume2007
DOIs
StatePublished - 2007

Fingerprint

Dive into the research topics of '2804 Thermal Stress Evaluation of Tubesheet Structures for Double-Wall-Tube Steam Generators of FBRs : (1) Study of Stress Inducement Mechanism'. Together they form a unique fingerprint.

Cite this