OS1422 減肉部を有する配管系の振動応答と損傷挙動(エネルギー機器の経年劣化に関する健全性評価,オーガナイズドセッション)

Translated title of the contribution: OS1422 Vibration response and failure behaviour of piping system with wall thinning

中村 いずみ, 大谷 章仁, 佐藤 祐二, 高田 一, 高橋 宏治, Izumi NAKAMURA

Research output: Contribution to conferencePresentation

Abstract

Tri-axial shake table tests on the piping system with wall thinning were conducted to clarify the effect of wall thinning on vibration characteristics and failure modes of the piping system. The test results show that the predominant frequency and the maximum response acceleration would be reduced due to the existence of wall thinning. Nondestructive inspection methods would be useful for detecting the damage before the failure caused by the seismic load.
Translated title of the contributionOS1422 Vibration response and failure behaviour of piping system with wall thinning
Original languageJapanese
StatePublished - 2009
EventM&M材料力学カンファレンス -
Duration: 16 Jul 2011 → …

Conference

ConferenceM&M材料力学カンファレンス
Period16/07/11 → …

Fingerprint

Dive into the research topics of 'OS1422 Vibration response and failure behaviour of piping system with wall thinning'. Together they form a unique fingerprint.