Abstract
Tri-axial shake table tests on the piping system with wall thinning were conducted to clarify the effect of wall thinning on vibration characteristics and failure modes of the piping system. The test results show that the predominant frequency and the maximum response acceleration would be reduced due to the existence of wall thinning. Nondestructive inspection methods would be useful for detecting the damage before the failure caused by the seismic load.
| Translated title of the contribution | OS1422 Vibration response and failure behaviour of piping system with wall thinning |
|---|---|
| Original language | Japanese |
| State | Published - 2009 |
| Event | M&M材料力学カンファレンス - Duration: 16 Jul 2011 → … |
Conference
| Conference | M&M材料力学カンファレンス |
|---|---|
| Period | 16/07/11 → … |